Wagner Meters offers Temperature Adjustment Table for RH readings

Tech-Tip-thumbnail-Cometary

ROGUE RIVER, OR — Wagner Meters (through a licensing agreement with CTLGroup) recently announced the exclusive release of a tool which estimates the relative humidity (RH) at service conditions of in-situ concrete RH (ASTM F2170) tests at non-service conditions, according to a release.

The purpose of the ASTM F2170 standard is to ensure that the equilibrium moisture level of the concrete is where it needs to be to successfully install the finished floor. With Wagner’s new Service Temperature Adjustment Table, flooring experts can better determine realistic project deadlines for flooring installations.pr-wagner-meters-video-thumb

To estimate the expected in-situ RH of the concrete floor slab at service conditions, you only need three things: The current non-service in situ temperature of the concrete slab, the RH measurements of the concrete slab and the Wagner Meters Service Temperature Adjustment Table.

The instructions to estimate the expected service RH are as follows:

  1. Determine the non-service condition temperature and the RH in the concrete slab.
  2. Find the expected RH at service conditions by determining where the measured non-service condition slab temperature and RH cross on the table. For example, if the measured RH is 87 percent, and the measured slab temp is 60 degrees Fahrenheit, then the expected service RH would be 90 percent.

pr-wagner-meters-temp-adjustment-table temperature adjustment table

“The Wagner Meters Service Temperature Adjustment Table gives project managers valuable information that will help to ensure the success of their projects,” Wagner Meters said in the release. “This information, combined with properly conducted RH measurements, as determined by the ASTM F2170 Standard, will decrease the risk of moisture-related flooring failures, costly delays, callbacks and even lawsuits. Failures, according to the Portland Cement Association, that have resulted in millions of dollars in damage annually to buildings in the United States.”


Wagner Meters emphasizes that the Service Temperature Adjustment Table is for estimation purposes only. The ASTM F2170 Standard mandates that service condition RH testing is done on concrete slabs before the finished flooring is installed. The acceptable level of RH is dependent on the flooring product and determined by the manufacturer.

Cleanfax Staff

Cleanfax provides cleaning and restoration professionals with information designed to help them manage and grow their businesses.

Follow Cleanfax Staff

Related Posts

Share This Article

Join Our Newsletter

Expert Videos

Popular Content

link building

The Power of Link Building for Your Cleaning Company’s Success

Cleanfax March/April 2023 digital

Cleanfax March/April 2023 Digital Edition Online Now

Leadership Tip passion over experience

Leadership Tips: Passion Over Experience 

Leadership Tip buyer persona

Leadership Tips: Developing a Buyer Persona

Leadership Tip boosting brand image eco-friendly

Leadership Tips: Being Eco-Friendly to Boost Brand Image

Polls

Have you ever been at fault for ruining something and then had to pay to replace it, such as a room of carpet or hard floor, an area rug, or piece of furniture?

View Results

Loading ... Loading ...

Upcoming Events

February 21, 2023

Simply Irresistible: How To Create Marketing Messages To Find New Customers